Microwave has been on the counter for a few weeks, since neutral on this one kept floating.

Microwave is now back in its cubby, and we have a big increase in counter space.

  • Switorik@sh.itjust.works
    link
    fedilink
    arrow-up
    7
    ·
    5 days ago

    You may want to check what year nec your state has adopted. It unfortunately is required now. Also 20A is required unless you have three or more outlets on the circuit (a duplex counts as two).

    • Nollij@sopuli.xyz
      link
      fedilink
      English
      arrow-up
      11
      ·
      5 days ago

      These usually only apply to new construction. Assuming it was built to code initially, you can replace parts to that same standard forever. You can’t just connect a 15 amp wire (usually 14-gauge) to a 20a outlet/breaker - that would be a horrible violation of all codes. But you can replace that existing 15a outlet as needed.

      You don’t have to run a 20a circuit unless you’re running a new line.

      • Switorik@sh.itjust.works
        link
        fedilink
        arrow-up
        2
        ·
        5 days ago

        You are correct, I assumed the microwave was on a 20A circuit. I’ve had inspectors require me to bring one for one repairs up to code. I suppose it’s an AHJ thing to keep in mind.

    • Swordgeek@lemmy.caOP
      link
      fedilink
      arrow-up
      2
      ·
      5 days ago

      Yeah, I know what my province’s code says and I followed it.

      Also, 20A??! Unless there are three OR MORE outlets??! I don’t know where that would be code. I don’t think I want to know.